Menu
The control stations with exterior PVC coating and interior yellow urethane are used for manual starting of AC or DC motors, status indicators presented by the motors through pilot lights and selection of starting mode of field engines.
80-84 (Shore A Durometer).
400 Volts/Mil at 60 cycles.
1000 hours (Atlas wet UV chamber).
200% min.
Polyvinyl chloride has a crystallization temperature of 5° F (-15° C).
PVC coating will burn if exposed to continuous flame or heat above 400°F (204°C).
Prolonged exposure to temperatures greater than 200°F (93°C) or fire may cause the PVC coating to release emissions potentially hazardous to the health of those exposed to them.
EFD/EFDB Control station with exterior PVC coating and interior with yellow urethane.
Representación | Tamaño del orificio en pulg. | Circuitos | Diagrama | Placa de identificación | Caja terminal | Caja de paso |
Caja rectangular† contacto momentáneo | ||||||
1/2" | 1 Circuito Universal | Arranque/Paro | RYC-EFDB150U1 | RYC-EFDCB150U1 | ||
3/4" | RYC-EFDB175U1 | RYC-EFDCB175U1 | ||||
1" | RYC-EFDB110U1 | RYC-EFDCB110U1 | ||||
1/2" | 2 Circuitos Universales | Arranque/Paro | RYC-EFDB150U2 | RYC-EFDCB150U2 | ||
3/4" | RYC-EFDB175U2 | RYC-EFDCB175U2 | ||||
1" | RYC-EFDB110U2 | RYC-EFDCB110U2 | ||||
Caja rectangular† - cabeza de hongo roja - contacto sostenido - para paro de emergencia | ||||||
1/2" | 1 Circuito Universal | Arranque/Paro | RYC-EFDB150UM1 | RYC-EFDCB150UM1 | ||
3/4" | RYC-EFDB175UM1 | RYC-EFDCB175UM1 | ||||
1" | RYC-EFDB110UM1 | RYC-EFDCB110UM1 | ||||
Caja rectangular doble† - contacto momentáneo | ||||||
1/2" | 2 Circuitos Universales | Arranque/Paro | RYC-EFD250U1 | RYC-EFDC250U1 | ||
3/4" | RYC-EFD275U1 | RYC-EFDC275U1 | ||||
1" | RYC-EFD210U1 | RYC-EFDC210U1 | ||||
1/2" | 4 Circuitos Universales | Arranque/Paro | RYC-EFD250U2 | RYC-EFDC250U2 | ||
3/4" | RYC-EFD275U2 | RYC-EFDC275U2 | ||||
1" | RYC-EFD210U2 | RYC-EFDC210U2 | ||||
3 dispositivosǂ - contacto momentáneo | ||||||
1/2" | 3 Circuitos Universales | Arranque/Paro | RYC-EFDL50U3 | RYC-EFDCL50U3 | ||
3/4" | RYC-EFDL75U3 | RYC-EFDCL75U3 | ||||
1" | RYC-EFDL10U3 | RYC-EFDCL10U3 |
† Malleable iron boxes and aluminum covers, to order aluminum boxes add the suffix “A” at the end, eg: RYC-EFDB175UM1A.
‡ Only malleable iron boxes.
Control station with push button start/stop, made of (specify material: copper-free aluminum or malleable iron), for Class I, Division 1 and 2, Groups B, C and D areas; Class II, Division 1 and 2, Groups E, F and G; Class III, NEMA 3, 7CD, 9EFG, 10 Amp., 600 Vac. Maximum, in box (specify Dead - End or Feed - Thru), of (specify diameter, e.g.: 3/4ӯ), of (select number of circuits, e.g.: 1 universal circuit), contact (specify momentary or sustained*) , with exterior PVC
coating and interior with yellow urethane, and stainless steel screws, REPSA Yellow Coat®.
*Mushroom head only.
Representación | Tamaño del orificio en pulg. | Circuitos | Diagrama | Placa de identificación | Caja terminal | Caja de paso |
Caja rectangular† | ||||||
1/2" | 1 Circuito Universal y 1 luz piloto | Arranque/Paro | RYC-EFDB150U1 | RYC-EFDCB150U1 | ||
3/4" | RYC-EFDB175U1 | RYC-EFDCB175U1 | ||||
1" | RYC-EFDB110U1 | RYC-EFDCB110U1 | ||||
1/2" | 2 Circuitos Universales y 1 luz piloto | Arranque/Paro | RYC-EFDB150U2 | RYC-EFDCB150U2 | ||
3/4" | RYC-EFDB175U2 | RYC-EFDCB175U2 | ||||
1" | RYC-EFDB110U2 | RYC-EFDCB110U2 | ||||
Caja rectangular doble† | ||||||
1/2" | 2 Circuitos Universales y 1 luz piloto | Arranque/Paro | RYC-EFD250J1U1 | RYC-EFDC250J1U1 | ||
3/4" | RYC-EFD275J1U1 | RYC-EFDC275J1U1 | ||||
1" | RYC-EFD210J1U1 | RYC-EFDC210J1U1 | ||||
1/2" | 2 Circuitos Universales y 2 luces piloto | Arranque/Paro | RYC-EFD250J2U2 | RYC-EFDC250J2U2 | ||
3/4" | RYC-EFD275J2U2 | RYC-EFDC275J2U2 | ||||
1" | RYC-EFD210J2U2 | RYC-EFDC210J2U2 |
† Malleable iron boxes and aluminum covers, to order aluminum boxes add the suffix “A” at the end, eg: RYC-EFDB150J1U1A.
‡ Only malleable iron boxes.
Control station with push button start/stop and pilot light, made of (specify material: copper-free aluminum or malleable iron), for Class I, Division 1 and 2, Groups B, C and D areas; Class II, Division 1 and 2, Groups E, F and G; Class III, NEMA 3, 7CD, 9EFG, 10 Amp., 600 Vac. Maximum, in box (specify Dead - End
or Feed - Thru), of (specify diameter, e.g.: 3/4”Ø), of (select number of circuits and pilot lights, e.g.: 1 universal circuit and 1 pilot light*), with exterior PVC coating and interior with yellow urethane, and stainless steel screws, REPSA Yellow Coat®.
*Specify pilot light color (Amber, Red, Green).