Flexible couplings are used in hazardous areas in a conduit system to achieve required curvatures or to allow movement and/or vibration of equipment or unit connections. For use in wiring lines sizes from ½” to 2” it is insulated against ground and direct fire from short circuits.
EXGJH couplings combine two male threads at their ends.
EXLK couplings combine a male thread and a female union.
80-84 (Shore A Durometer).
400 Volts/Mil at 60 cycles.
1000 hours (Atlas wet UV chamber).
200% min.
Polyvinyl chloride has a crystallization temperature of 5° F (-15° C).
PVC coating will burn if exposed to continuous flame or heat above 400°F (204°C).
Prolonged exposure to temperatures greater than 200°F (93°C) or fire may cause the PVC coating to release emissions potentially hazardous to the health of those exposed to them.
EXGJH and EXLK Flexible coupling with exterior PVC coating and interior coating of the nipples with yellow urethane
Flex lenght (Inches) | Conduit size (inches) | Male - Male | Female - Male | Flex lenght (Inches) | Conduit size (inches) | Male - Male | Female - Male | |
4” | 1/2” | RYC-EXGJH14 | RYC-EXLK14 | 21” | 1-1/2” | RYC-EXGJH521 | RYC-EXLK521 | |
4” | 3/4” | RYC-EXGJH24 | RYC-EXLK24 | 21” | 2” | RYC-EXGJH621 | RYC-EXLK621 | |
6” | 1/2” | RYC-EXGJH16 | RYC-EXLK16 | 24” | 1/2” | RYC-EXGJH124 | RYC-EXLK124 | |
6” | 3/4” | RYC-EXGJH26 | RYC-EXLK26 | 24” | 3/4” | RYC-EXGJH224 | RYC-EXLK224 | |
6” | 1” | RYC-EXGJH36 | RYC-EXLK36 | 24” | 1” | RYC-EXGJH324 | RYC-EXLK324 | |
8” | 1/2” | RYC-EXGJH18 | RYC-EXLK18 | 24” | 1-1/4” | RYC-EXGJH424 | RYC-EXLK424 | |
8” | 3/4” | RYC-EXGJH28 | RYC-EXLK28 | 24” | 1-1/2” | RYC-EXGJH524 | RYC-EXLK524 | |
8” | 1” | RYC-EXGJH38 | RYC-EXLK38 | 24” | 2” | RYC-EXGJH624 | RYC-EXLK624 | |
10” | 1/2” | RYC-EXGJH110 | RYC-EXLK110 | 27” | 1/2” | RYC-EXGJH127 | RYC-EXLK127 | |
10” | 3/4” | RYC-EXGJH210 | RYC-EXLK210 | 27” | 3/4” | RYC-EXGJH227 | RYC-EXLK227 | |
10” | 1” | RYC-EXGJH310 | RYC-EXLK310 | 27” | 1” | RYC-EXGJH327 | RYC-EXLK327 | |
12” | 1/2” | RYC-EXGJH112 | RYC-EXLK112 | 27” | 1-1/4” | RYC-EXGJH427 | RYC-EXLK427 | |
12” | 3/4” | RYC-EXGJH212 | RYC-EXLK212 | 27” | 1-1/2” | RYC-EXGJH527 | RYC-EXLK527 | |
12” | 1” | RYC-EXGJH312 | RYC-EXLK312 | 27” | 2” | RYC-EXGJH627 | RYC-EXLK627 | |
12” | 1-1/4” | RYC-EXGJH412 | RYC-EXLK412 | 30” | 1/2” | RYC-EXGJH130 | RYC-EXLK130 | |
12” | 1-1/2” | RYC-EXGJH512 | RYC-EXLK512 | 30” | 3/4” | RYC-EXGJH230 | RYC-EXLK230 | |
12” | 2” | RYC-EXGJH612 | RYC-EXLK612 | 30” | 1” | RYC-EXGJH330 | RYC-EXLK330 | |
15” | 1/2” | RYC-EXGJH115 | RYC-EXLK115 | 30” | 1-1/4” | RYC-EXGJH430 | RYC-EXLK430 | |
15” | 3/4” | RYC-EXGJH215 | RYC-EXLK215 | 30” | 1-1/2” | RYC-EXGJH530 | RYC-EXLK530 | |
15” | 1” | RYC-EXGJH315 | RYC-EXLK315 | 30” | 2” | RYC-EXGJH630 | RYC-EXLK630 | |
15” | 1-1/4” | RYC-EXGJH415 | RYC-EXLK415 | 33” | 1/2” | RYC-EXGJH133 | RYC-EXLK133 | |
15” | 1-1/2” | RYC-EXGJH515 | RYC-EXLK515 | 33” | 3/4” | RYC-EXGJH233 | RYC-EXLK233 | |
15” | 2” | RYC-EXGJH615 | RYC-EXLK615 | 33” | 1” | RYC-EXGJH333 | RYC-EXLK333 | |
18” | 1/2” | RYC-EXGJH118 | RYC-EXLK118 | 33” | 1-1/4” | RYC-EXGJH433 | RYC-EXLK433 | |
18” | 3/4” | RYC-EXGJH218 | RYC-EXLK218 | 33” | 1-1/2” | RYC-EXGJH533 | RYC-EXLK533 | |
18” | 1” | RYC-EXGJH318 | RYC-EXLK318 | 33” | 2” | RYC-EXGJH633 | RYC-EXLK633 | |
18” | 1-1/4” | RYC-EXGJH418 | RYC-EXLK418 | 36” | 1/2” | RYC-EXGJH136 | RYC-EXLK136 | |
18” | 1-1/2” | RYC-EXGJH518 | RYC-EXLK518 | 36” | 3/4” | RYC-EXGJH236 | RYC-EXLK236 | |
18” | 2” | RYC-EXGJH618 | RYC-EXLK618 | 36” | 1” | RYC-EXGJH336 | RYC-EXLK336 | |
21” | 1/2” | RYC-EXGJH121 | RYC-EXLK121 | 36” | 1-1/4” | RYC-EXGJH436 | RYC-EXLK436 | |
21” | 3/4” | RYC-EXGJH221 | RYC-EXLK221 | 36” | 1-1/2” | RYC-EXGJH536 | RYC-EXLK536 | |
21” | 1” | RYC-EXGJH321 | RYC-EXLK321 | 36” | 2” | RYC-EXGJH636 | RYC-EXLK636 | |
21” | 1-1/4” | RYC-EXGJH421 | RYC-EXLK421 |
Flexible coupling (specify type: EXGJH for female ends with removable nipple or EXLK for one female end with removable nipple and another with UNF type union), with bronze mesh, for Class I areas, Division 1 and 2, groups A , B, C and D; Class II, Division 1 and 2, groups E, F and G; Class III, (specify diameter and length, e.g.: 3/4”Ø and 15” length), with exterior PVC coating and interior coating of the nipples with yellow urethane, REPSA Yellow Coat®.
Subscribe to our newsletter to receive up-to-date news and articles about the company.
Over 28 years developing effective solutions to corrosion issues in industrial electrical conduit.
Este sitio web utiliza cookies para mejorar su experiencia. Asumiremos que está de acuerdo con esto, pero puede optar por no participar si lo desea. Leer más
Chatea con un asesor